Instructions for Hub Board Removal and Replacement on the Dioplex 4mm
- Verify Power Disconnection
- Ensure all power to the cabinet is disconnected or turned off.
- Check the breakers or use a voltage meter to confirm no power is present.
- Take a Photo for Reference
- Before removing any parts, take a clear photo of the hub board and its connections to ensure proper reassembly.
- Prepare for Hub Removal
- Identify and remove the following components before removing the hub board:
- Power Supply
- Data Cables
- Receiving Card
- Remove the Hub Board
- Start by disconnecting the power supply cords.
- Remove each data cable from the hub board.
- Unscrew all eight screws securing the hub board.
- Gently remove the hub board from the frame.
- Transfer the Receiving Card
- Detach the receiving card from the old hub board and attach it to the new hub board.
- Install the New Hub Board
- Carefully place the new hub board into position, ensuring proper alignment.
- Apply gentle pressure at each pin location of the mods to secure the hub board.
- Replace all eight screws to secure the hub board in place.
- Reconnect Components
- Reattach the wires from the power supply.
- Plug the data cables back into their respective ports.
- Finally, connect the wires from the power supply at the bottom.
- Final Check
- Verify that all connections are secure and the hub board is properly installed.
Urgent? reach out to our service team
+1 (515) 349-7708